Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 79
Filter
1.
Rev. bras. ortop ; 58(5): 766-770, Sept.-Oct. 2023. tab, graf
Article in English | LILACS | ID: biblio-1529938

ABSTRACT

Abstract Objective The study aims to demonstrate an evaluation method to predict the functional success of total wrist arthrodesis (TWA) and assist its indication. Methods A prospective study including ten patients submitted to (TWA) posttraumatic arthritis. Exclusion criteria were patients who lost postoperative follow-up or incomplete information in the medical record. The objective functional assessment (handgrip strength, three-point pinch, lateral pinch and pulp-pulp pinch) and the subjective functional assessment (DASH, PRWE, EVA) were evaluated in 3 different periods: (1) Before surgery without articular anesthesia, (2) Before surgery under articular anesthesia and (3) 12 weeks after the surgical procedure. Results There was an increase in handgrip strength in all three pinches measurements after pain relief, both after joint anesthesia and after the consolidation of the arthrodesis (p < 0.05). In the comparisons between the subjective evaluations (DASH, PRWE and VAS), the patients had better scores in the postoperative evaluation after 12 weeks (p < 0.05). There was no statistical difference when comparing the mean strength values found after anesthesia and after 12 weeks of TWA. Conclusion the outcomes could propose an assessment protocol for patients with indication for TWA, in which patients with good response to intra-articular anesthetic infiltration would benefit from the effects of the surgical procedure.


Resumo Objetivo O estudo tem como objetivo demonstrar um método de avaliação para predizer o sucesso funcional da artrodese total do punho (ATP) e auxiliar na sua indicação. Métodos Um estudo prospectivo incluindo dez pacientes submetidos a ATP por artrite pós-traumática. Os critérios de exclusão foram pacientes que perderam o acompanhamento pós-operatório ou informações incompletas no prontuário. A avaliação funcional objetiva (força de preensão manual, pinça de três pontos, pinça lateral e pinça polpa-a-polpa) e a avaliação funcional subjetiva (DASH, PRWE, EVA) foram avaliadas em 3 momentos diferentes: (1) Antes da cirurgia sem anestesia articular, (2) Antes da cirurgia sob anestesia articular e (3) 12 semanas após o procedimento cirúrgico. Resultados Houve aumento da força de preensão palmar nas três medidas de pinça após o alívio da dor, tanto após a anestesia articular quanto após a consolidação da artrodese (p < 0,05). Nas comparações entre as avaliações subjetivas (DASH, PRWE e VAS), os pacientes tiveram melhores escores na avaliação pós-operatória após 12 semanas (p < 0,05). Não houve diferença estatística ao comparar os valores médios de força encontrados após a anestesia e após 12 semanas de ATP.


Subject(s)
Humans , Arthrodesis , Wrist Injuries , Wrist Joint/surgery
2.
Rev. bras. ortop ; 58(4): 611-616, July-Aug. 2023. tab, graf
Article in English | LILACS | ID: biblio-1521794

ABSTRACT

Abstract Objective To evaluate the open surgical treatment for carpal tunnel syndrome as a risk factor for the development of stenosing tenosynovitis that results in trigger finger and De Quervain disease. Materials and Methods A retrospective study analyzing the medical records of patients submitted to open surgical release of carpal tunnel syndrome between 2010 and 2021 in a secondary- and tertiary-level hospital. The following data were collected: pathological history, duration of the follow-up after the surgical treatment for carpal tunnel syndrome, development of trigger finger or De Quervain tenosynovitis, affected fingers, and the interval between the end of surgery and symptom onset. Results We evaluated 802 patients of both genders and with a mean age of 50.1 (±12.6) years. The mean follow-up was of 13 (±16.4) months. The mean time until the development of trigger finger was of 61.4 months, and of 73.7 months for De Quervain disease. The incidence of development of De Quervain disease was of 4.12%, and for trigger finger it was of 10.2%. The most affected digits were the thumb (47.6%), the middle (24.4%), and the ring finger (8.54%). Age was the only factor that showed an association with the risk of developing trigger finger, with an increase of 2% for each increase in age of 1 year. Conclusion The incidence rates for the development of De Quervain disease (4.12%) and trigger finger (10.2%) after the surgical treatment for carpal tunnel syndrome were like those described in the literature. Only age was a factor that influenced the development of trigger finger.


Resumo Objetivo Avaliar o tratamento cirúrgico aberto da síndrome do túnel do carpo como fator de risco para o desenvolvimento das tenossinovites estenosantes formadoras do dedo em gatilho e da doença de De Quervain. Materiais e Métodos Estudo retrospectivo com análise dos prontuários de pacientes submetidos a liberação cirúrgica aberta da síndrome do túnel do carpo entre 2010 e 2021 em hospital de níveis secundário e terciário. Os seguintes dados foram coletados: histórico patológico, tempo de acompanhamento após o tratamento cirúrgico da síndrome do túnel do carpo, desenvolvimento de dedo em gatilho ou tenossinovite de De Quervain, dedos acometidos, e tempo decorrido entre o fim da cirurgia e o aparecimento dos sintomas. Resultados Foram avaliados 802 pacientes de ambos os sexos com média de idade de 50,1 (±12,6) anos. O tempo médio de seguimento foi de 13 (±16,4) meses. O tempo médio de desenvolvimento de dedo em gatilho foi de 61,4 meses, e o da doença de De Quervain, de 73,7 meses. A incidência de desenvolvimento da doença de De Quervain foi de 4,12% e a de dedo em gatilho, de 10,2%. Os dedos mais acometidos foram o polegar (47,6%), o médio (24,4%) e o anular (8,54%). A idade foi único fator que demonstrou associação com o risco de desenvolvimento de dedo em gatilho, com aumento de 2% a cada ano a mais de idade. Conclusão As taxas de incidência de desenvolvimento de doença de De Quervain (4,12%) e de dedo em gatilho (10,2%) após tratamento cirúrgico da síndrome do túnel do carpo foram semelhantes às descritas na literatura. Apenas a idade se apresentou como fator influenciador no desenvolvimento de dedo em gatilho.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Carpal Tunnel Syndrome , De Quervain Disease , Trigger Finger Disorder
3.
Rev. bras. ortop ; 57(3): 455-461, May-June 2022. tab, graf
Article in English | LILACS | ID: biblio-1388017

ABSTRACT

Abstract Objective The purpose of the present study was to evaluate the rate of patency in the postoperative period of arterial injuries of the forearm secondary to penetrating trauma. The injuries were subjected to primary repair and examined with the Allen test and a handheld Doppler device, and the results were later confirmed with Doppler ultrasonography. Methods Eighteen patients were included, with a total of 19 arterial lesions, 14 ulnar lesions, and 5 radial lesions; one patient had lesions on both forearms. All patients underwent surgery and three clinical evaluations: the Allen test and assessment of arterial blood flow by a handheld Doppler device at 4 and 16 weeks after surgery and Doppler ultrasonography performed at 12 weeks after surgery. Results At the first clinical evaluation, 77% of the patients had patency based on the Allen test, and 72% had a pulsatile sound identified by the handheld Doppler device. In the second evaluation, 61% of the patients had patency based on the Allen test, and the rate of pulsatile sound by the handheld Doppler device was 72%, similar to that observed 2 months earlier. Based on the Doppler ultrasonography evaluation (~12 weeks after surgery), the success rate for arteriorrhaphy was 88%. Regarding the final patency (Doppler ultrasonography evaluation) and trauma mechanism, all patients with penetrating trauma had patent arteries. Conclusion We cde that clinical evaluation using a handheld Doppler device and the Allen test is reliable when a patent artery can be palpated. However, if a patent artery cannot be located during a clinical examination, ultrasonography may be required.


Resumo Objetivo O objetivo deste estudo foi avaliar a taxa de perviedade pós-operatória de lesões arteriais do antebraço secundárias a traumatismo penetrante. As lesões foram submetidas a reparo primário e examinadas com o teste de Allen e um dispositivo Doppler portátil; posteriormente, os resultados foram confirmados à ultrassonografia com Doppler. Métodos Dezoito pacientes foram incluídos, com um total de 19 lesões arteriais, 14 lesões ulnares e 5 lesões radiais; um paciente tinha lesões em ambos os antebraços. Todos os pacientes foram submetidos à cirurgia e três avaliações clínicas: o teste de Allen e a avaliação do fluxo sanguíneo arterial com um dispositivo portátil de Doppler na 4ª e 16ª semanas após a cirurgia e ultrassonografia com Doppler 12 semanas após o procedimento. Resultados Na primeira avaliação clínica, 77% dos pacientes apresentavam perviedade segundo o teste de Allen e 72% apresentavam som pulsátil identificado pelo Doppler portátil. Na segunda avaliação, 61% dos pacientes apresentaram perviedade com base no teste de Allen e a taxa de som pulsátil ao Doppler portátil foi de 72%, semelhante à observada 2 meses antes. À ultrassonografia com Doppler (cerca de 12 semanas após a cirurgia), a taxa de sucesso da arteriorrafia foi de 88%. Em relação à perviedade final (avaliação por ultrassonografia com Doppler) e mecanismo de trauma, todos os pacientes com traumatismo penetrante apresentavam artérias pérvias. Conclusão Concluímos que a avaliação clínica com um dispositivo Doppler portátil e o teste de Allen é confiável caso a artéria pérvia possa ser palpada. No entanto, a ultrassonografia pode ser necessária em caso de impossibilidade de localização de uma artéria pérvia durante o exame clínico.


Subject(s)
Humans , Ulnar Artery/injuries , Ultrasonography, Doppler , Forearm Injuries
4.
Rev. bras. ortop ; 57(1): 69-74, Jan.-Feb. 2022. tab, graf
Article in English | LILACS | ID: biblio-1365758

ABSTRACT

Abstract Objective To evaluate the use of external fixators in the delta-type kickstand configuration as an adjuvant method in the postoperative period of patients submitted to free flaps in the lower limbs. Methods A total of 17 external delta fixators were used in patients submitted to free flaps in the lower limbs. The surgical technique was performed in a standardized manner, with the distal pin located 6 cm proximally to the anastomosis, and the proximal pin, 6 cm distally to the anterior tuberosity of the tibia. Results The mean age of the sample was of 34.76 years (range: 15 to 66 years). In total, 11 men and 6 women were selected. The posterior tibial artery was used in 14 cases, and the anterior tibial artery, in 3 cases. The mean time of use of the external fixators was of 3.88 weeks. The rate of reoperation was of 17.64%; that of retail loss was of 11.76%; that of success rate was of 88.23%; and the rate of infection was of 5.9%. Conclusion The use of delta-type fixators as an adjunct method in the postoperative period is reliable; however, more studies are needed to evaluate its true role in the postoperative period.


Resumo Objetivo Avaliar o uso de fixadores externos, na configuração kickstand do tipo delta, como método adjuvante no período pós-operatório de pacientes submetidos a retalhos livres nos membros inferiores. Métodos Ao todo, 17 fixadores externos do tipo delta foram utilizados em pacientes submetidos a retalhos livres nos membros inferiores. A técnica cirúrgica foi realizada de forma padronizada, com o pino distal localizado 6 cm proximal à anastomose, e o pino proximal, 6cm distal à tuberosidade anterior da tíbia. Resultados A idade média da amostra foi de 34,76 anos (variação: 15 a 66 anos). Foram selecionados 11 homens e 6 mulheres. Utilizou-se a artéria tibial posterior em 14 casos, e a tibial anterior, em 3 casos. O tempo médio de uso dos fixadores externos foi de 3,88 semanas. A taxa de reoperação foi de 17,64%; a de perda do retalho foi de 11,76%; a de sucesso foi de 88,23%; e a taxa de infecção foi de 5,9%. Conclusão O uso de fixadores do tipo delta como método adjuvante no pós-operatório é confiável; porém, mais estudos são necessários para avaliar seu verdadeiro papel no pós-operatório.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Fractures, Bone , Perforator Flap , Myocutaneous Flap , Microsurgery
5.
Acta ortop. bras ; 30(1): e246704, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1355579

ABSTRACT

ABSTRACT Introduction Comparison of different surgical techniques to treat patients with rhizarthrosis or carpometacarpal osteoarthritis of the thumb. Materials and Methods A systematic review was conducted using three electronic databases. Randomized, controlled trials in patients who underwent surgery for the treatment of rhizarthrosis were included. The literature review followed the PRISMA protocol. Results A total of 15 articles involving a total population of 958 patients were selected. Seven different surgical techniques were compared. Conclusions We conclude that no procedure is superior to another in terms of pain, physical function, overall patient assessment, range of motion, or strength. Outcome measurements should be standardized to enable better comparison between surgical techniques. Level of evidence II, Systematic Review.


RESUMO Introdução Comparação de diferentes técnicas cirúrgicas em pacientes com rizartrose ou osteoartrite carpometacárpica do polegar. Materiais e Métodos A revisão sistemática foi conduzida em três bancos de dados eletrônicos. Foram incluídos estudos clínicos randomizados e controlados com pacientes submetidos ao tratamento cirúrgico para tratamento de rizartrose. A revisão da literatura seguiu o protocolo PRISMA. Resultados Foram selecionados 15 artigos, envolvendo uma população total de 958 pacientes. Foram comparadas sete técnicas cirúrgicas distintas. Conclusões Concluímos que nenhum procedimento é superior a outro em termos de dor, função física, avaliação geral do paciente, amplitude de movimento ou força. A mensuração dos desfechos obtidos devem ser padronizadas a fim de possibilitar melhor comparação entre as técnicas cirúrgicas assim como, permitir uma análise estatística fidedigna. Nível de Evidência II; Revisão Sistemática.

6.
Acta ortop. bras ; 26(6): 423-427, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-973591

ABSTRACT

ABSTRACT Background: Distal radius fractures are one of the most common orthopedic injuries and appear in various patterns. Volar plate fixation is not always considered the gold standard treatment. Objective: To measure the resistance of a fragment-specific fixation assembly model obtained by plate fixation associated with different K-wire sizes. Method: In this original experimental study, novel II, axial compression of bone materials was tested. Results: In both groups, the maximum force supported by the fixation method in our study was ten times greater than the physiological load to which the wrist was subjected under physiological conditions. Discussion: In this study, we obtained encouraging results when compared to results reported in the literature. Our study showed that our bone fixating system was mechanically adequate for articular fractures of the intermediate column of the radius (Melone classification). The results were similar or superior to the results of pressure resistance and stiffness when data from the literature was used as reference. Conclusion: The proposed fixation method demonstrated adequate resistance for fixation of the intermediate column of the distal radius. Increasing K wire size caused augmented resistance of the fixation. Level of Evidence II, Prospective comparative study.


RESUMO Introdução: A fratura da extremidade distal do rádio é uma afecção frequente, com variedade de apresentações e nem sempre são passíveis de fixação volar única. Objetivo: Quantificar a resistência obtida no modelo experimental de fixação do fragmento específico, utilizando fio de Kirschner pré moldado, associado a fixação proximal com placa e parafuso. Métodos: Estudo experimental original, nível II, no qual foram realizados ensaios mecânicos com objetivo de avaliar a resistência a compressão axial. Resultados: Os valores de força máxima suportada pelo método de fixação foram pelo menos 10x maiores do que a carga fisiológica a qual o punho é submetido. Discussão: A fixação do tipo fragmento específico vem se mostrando útil e segura, permitindo uma mobilidade precoce segura. Os resultados analisados demonstraram que a montagem proposta em nosso estudo foi mecanicamente adequada para a fixação das fraturas articulares da borda volar ulnar (classificação de Melone) do rádio, tendo resultados semelhantes ou superiores quando comparados a literatura, avaliando a rigidez e a pressão o qual o sistema foi submetido. Conclusão: O método de fixação proposto demonstrou resistência adequada para fixação das fraturas da coluna intermediária do rádio. O aumento da espessura do fio provocou um aumento da força resistida da montagem. Nível de Evidência II, Estudo prospectivo comparativo.

7.
Acta ortop. bras ; 25(6): 291-294, Nov.-Dec. 2017. graf
Article in English | LILACS | ID: biblio-886505

ABSTRACT

ABSTRACT Objective: This article provides details and tips on the dry arthroscopic technique, based on our experience and its clinical applications. Method: The technique was applied to 65 patients (33 men and 32 women) aged between 20 and 62 years (average of 35.4 years) for treating: synovial cyst resection, scapholunate ligament injury repair, ulnocarpal impact correction, triangular fibrocartilage injury repair, and assisted reduction of distal radius fractures. Results: A minimally invasive intra-articular evaluation has been observed as a benefit, with low infection rate, small scars, and high rates of early recovery, without affecting intra-articular fluid use, reducing the risk of compartment syndrome and infiltrated soft tissues, in the case of need for associated open surgery. As for the difficulties, we report the surgeon's view, which is commonly prevented by optical blurring or debris that hit the lens, and the need for radiofrequency care, since the heat generated is dissipated with greater difficulty than in the classical technique. Conclusion: Dry arthroscopy emerges as an effective choice to treat wrist pathologies, however, deep knowledge and ease with the classical technique, as well as a learning curve, are key to obtain a good outcome. Level of Evidence V, Expert Opinion.


RESUMO Objetivo: Este artigo apresenta detalhes e dicas sobre a técnica de artroscopia seca, baseada em nossa experiência e em suas aplicações clínicas. Método: A técnica foi aplicada em 65 pacientes (33 homens e 32 mulheres) com idades entre 20 e 62 anos (média de 35,4 anos) para o tratamento de ressecção de cisto sinovial, reparo de lesão do ligamento escafo-semilunar, correção do impacto ulnocarpal, reparo de lesão da fibrocartilagem triangular e assistência na redução de fraturas da parte distal do rádio. Resultados: A avaliação intra-articular minimamente invasiva foi observada como benefício, com baixo índice de infecção, cicatrizes pequenas e altas taxas de recuperação precoce, sem prejuízo do uso intra-articular de líquido, reduzindo o risco de síndrome compartimental e tecidos moles infiltrados, no caso de necessidade de cirurgia aberta associada. Quanto às dificuldades, relatamos a visibilidade para o cirurgião, comumente impedida pelo turvação da óptica ou detritos salpicados na lente e a necessidade de cautela com a radiofrequência, pois o calor gerado é dissipado com maior dificuldade do que na técnica clássica. Conclusão: A artroscopia seca surge como opção efetiva no tratamento das patologias de punho, entretanto, o conhecimento profundo e as facilidades com a técnica clássica, bem como a curva de aprendizado, são fundamentais para obter um bom resultado. Nível de Evidência V, Opinião do Especialista.

8.
Acta ortop. bras ; 24(3): 159-163, May-June 2016. tab, Ilus
Article in English | LILACS | ID: lil-782000

ABSTRACT

OBJECTIVE: To evaluate the outcome of olecranon bone graft and compression screw for the treatment of nonunion of the Lichtman type I scaphoid. METHOD: We evaluated 15 patients of 32 who underwent surgical treatment for nonunion of the Lichtman type I scaphoid with olecranon bone graft and screw compression. RESULTS: We obtained 100% consolidation in our sample. The mean flexion of the wrist on the affected side was 68° and 75° on the non-affected side. The average extension was 63° and 72°, respectively. The average grip strength was 35 kgf. This corresponds to 98% of the handgrip strength of the non-affected side, which was 37 kgf. The DASH score averaged 5 points. CONCLUSION: We believe that the use of bone graft obtained from the olecranon and secured with cannulated screw is a resolute technique for cases of linear nonunion of the Lichtmann type I scaphoid. It has the advantages of a new anesthesia for removal of the graft and the access is easy, providing a good exposure for removal and good aesthetic results. Level of evidence IV. Case series


Subject(s)
Humans , Osteoarthritis , Wrist Joint , Carpal Bones , Bone Transplantation , Scaphoid Bone/injuries , Olecranon Process
9.
Radiol. bras ; 49(3): 144-149, tab, graf
Article in English | LILACS | ID: lil-787606

ABSTRACT

Abstract Objective: To assess imaging parameters related to the morphology of the glenohumeral joint in children with unilateral brachial plexus birth palsy (BPBP), in comparison with those obtained for healthy shoulders. Materials and Methods: We conducted a retrospective search for cases of unilateral BPBP diagnosed at our facility. Only patients with a clinical diagnosis of unilateral BPBP were included, and the final study sample consisted of 10 consecutive patients who were assessed with cross-sectional imaging. The glenoid version, the translation of the humeral head, and the degrees of glenohumeral dysplasia were assessed. Results: The mean diameter of the affected humeral heads was 1.93 cm, compared with 2.33 cm for those of the normal limbs. In two cases, there was no significant posterior displacement of the humeral head, five cases showed posterior subluxation of the humeral head, and the remaining three cases showed total luxation of the humeral head. The mean glenoid version angle of the affected limbs (90-α) was -9.6º, versus +1.6º for the normal, contralateral limbs. Conclusion: The main deformities found in this study were BPBP-associated retroversion of the glenoid cavity, developmental delay of the humeral head, and posterior translation of the humeral head.


Resumo Objetivo: Avaliar os parâmetros de imagem relacionados com a morfologia da articulação glenoumeral em crianças com paralisia obstétrica do plexo braquial (POPB) unilateral, comparando-os com os observados em ombros saudáveis. Materiais e Métodos: Foi realizada uma busca retrospectiva de casos de POPB unilateral diagnosticados em nossa instituição. Somente foram incluídos os pacientes com diagnóstico clínico de POPB unilateral, e a amostra final do estudo consistiu em 10 pacientes consecutivos avaliados por meio de imagens transversais. Foram avaliados a retroversão da cavidade glenoide, a translação da cabeça do úmero e o grau de displasia glenoumeral. Resultados: A média do diâmetro da cabeça do úmero foi 1,93 cm nos membros afetados e 2,33 cm nos membros normais. Em dois casos, não houve deslocamento posterior significativo da cabeça do úmero, cinco casos apresentaram subluxação posterior da cabeça do úmero, e os três casos restantes apresentaram luxação total da cabeça do úmero. A média do ângulo de retroversão glenoide dos membros afetados (90-α) foi -9,6º, ao passo que a dos membros contralaterais normais foi +1,6º. Conclusão: As principais deformidades encontradas neste estudo foram retroversão da cavidade glenoide relacionada com POPB, atraso no desenvolvimento da cabeça do úmero e translação posterior da cabeça do úmero.

10.
Acta ortop. bras ; 23(6): 311-314, tab, graf
Article in English | LILACS | ID: lil-764401

ABSTRACT

ABSTRACTOBJECTIVE: To evaluate functional outcomes of patients submit-ted to proximal row carpectomy for the treatment of wrist arthri-tisMETHODS: This is a retrospective study using wrist motion and grip strenght of patients diagnosed with Kienböck disease and scaphoid non-union surgically treated by this techniqueRESULTS: Eleven patients with 2-year follow-up were evaluated. Wrist motion (flexion, extension and ulnar deviation) and grip strength were significantly better from preoperative values. Ho-wever, no difference in radial deviation was observed in these patientsCONCLUSION: Proximal row carpectomy provides an alternative option for treatment of wrist arthritis, resulting in better active range of motion and grip strength in the long run. Level of Evidence IV, Case Series.

11.
Acta ortop. bras ; 23(1): 19-21, Jan-Feb/2015. tab, fig
Article in English | LILACS | ID: lil-735717

ABSTRACT

Objective: To determine the profile of patients with humeral diaphyseal fractures in a tertiary hospital. Methods: We conducted a survey from January 2010 to July 2012, including data from patients classified under humeral diaphyseal fracture (S42.3) according to the International Classification of Diseases (ICD-10). The variables analyzed were: age, gender, presence of radial nerve injury, causal agent and the type of treatment carried out. Results: The main causes of trauma were car accidents. The radial nerve lesion was present in some cases and was caused by the same trauma that caused the fracture or iatrogenic injury. Most of these fractures occurred in the middle third of humeral diaphysis and was treated conservatively. Conclusion: The profile of patients with fracture of humeral shaft, in this specific sample, was composed mainly of adult men involved in traffic accidents; the associated radial nerve lesion was present in most of these fractures and its cause was strongly related to the trauma mechanism. Level of Evidence II, Retrospective Study.


Subject(s)
Humans , Male , Female , Radial Nerve/injuries , Accidents, Traffic , Epidemiology, Descriptive , Humeral Fractures
12.
Acta ortop. bras ; 22(5): 269-274, Sep-Oct/2014. ilus, tab, graf
Article in English, Portuguese | LILACS | ID: lil-783279

ABSTRACT

Analisar a influência das placas de aço de osteossíntesesobre a velocidade de propagação de ultrassom (VU) através doosso. Métodos: Foram medidas as VUs subaquáticas transversalcoronal e sagital no osso intacto e a seguir nas montagens domesmo osso com dois tipos de placas de osteossíntese (DCP esemitubular), fixadas na face dorsal do osso. O primeiro sinal achegar (first arriving signal, FAS) foi o parâmetro ultrassônico utilizadopara as medidas, tomando os diâmetros coronal e sagitalcomo distância percorrida para o cálculo da VU. Comparaçõesestatísticas intergrupos foram feitas ao nível de significância de1% (p<0,01). Resultados: A VU foi maior em ossos intactos doque nas montagens osso-placa, mas as diferenças entre os gruposnão foram significativas para a maioria das comparações(p=0,0132 a 0,9884), indicando que as placas de aço não interferemsignificantemente com a VU através das montagens osso--placa. Conclusão: O efeito de redução da VU nas montagensfoi atribuído ao maior coeficiente de reflexão do aço comparadoao osso e à água. Do ponto de vista prático, a ultrassonometriapode ser empregada para a avaliação da consolidação de fraturasfixadas com placas de aço. Estudo experimental...


To analyze the influence of steel plates for osteosynthesison the velocity of ultrasound propagation (VU) through the bone.Methods: The transverse coronal and sagittal velocity of ultrasoundpropagation underwater were measured on the intact bone and thenon assemblies of the same bone with two types of osteosynthesisplates (DCP and semi tubular), fixed onto the dorsal side of thebones. The first arriving signal (FAS) was the ultrasound parameterused, taking the coronal and sagittal diameters as the distancesto calculate velocity. Intergroup statistical comparisons were madeat significance level of 1% (p<0.01). Results: Velocity was higheron the intact bones than on the bone-plate assemblies and higherfor the semitubular than for the compression plates, althoughdifferences were not statistically significant for most comparisons(p=0.0132 to 0.9884), indicating that the steel plates do not interferesignificantly with ultrasound wave propagation through thebone-plate assemblies. Conclusion: The velocity reduction effectwas attributed to the greater reflection coefficient of the steel ascompared to that of bone and water. Ultrasonometry can, thus, beused in the evaluation of healing of fractures fixed with steel plates.Experimental study...


Subject(s)
Humans , Acoustics , Steel , Fracture Fixation, Internal , Bone and Bones , Bone Plates , Ultrasonics
13.
Acta fisiátrica ; 20(1): 14-19, mar. 2013.
Article in English, Portuguese | LILACS | ID: lil-689479

ABSTRACT

A incidência de lesões traumáticas dos membros superiores em um hospital terciário além de ser elevada, possui uma grande variedade. Neste sentido torna-se importante a criação de um banco de dados único, para conhecer o perfil dos pacientes atendidos. Objetivo: traçar o perfil dos pacientes com lesões traumáticas dos membros superiores, atendidos pela Fisioterapia no Centro de Reabilitação do Hospital das Clínicas de Ribeirão. Método: foram avaliadas 223 fichas de pacientes (58 mulheres e 116 homens), com idade média de 34,54 (± 19,05) anos, encaminhados pelo ambulatório de ortopedia do referido hospital. Resultados: do total de casos analisados, as lesões de punho e mão obtiveram maior incidência (60,99%), seguidos por lesões de ombro (20,63%), cotovelo (12,55%), braço (3,59%) e antebraço (2,24%). Nas lesões de punho e mão o mecanismo de trauma com maior porcentagem foi o acidente de moto, relacionado com as fraturas múltiplas de ossos da mão. Queda da própria altura, acidente motociclístico e queda de escada foram os mecanismos de trauma, correlacionando com as fraturas de úmero proximal, luxação de ombro e fraturas de escápula respectivamente. Conclusão: Foi verificada a incidência de lesão, mecanismo de trauma e as características da população para futuramente aprimorar os protocolos específicos para as disfunções e investir em campanhas de prevenção.


The incidence of traumatic injuries of the upper limbs in a tertiary hospital has a wide variety. This is why the creation of a unified database becomes important-to know the patients’ profile. Objective: this study sought to determine the profile of patients with traumatic injuries of the upper limbs, treated by Physical Therapy in Rehabilitation Center of the Clinics Hospital of Ribeirão Preto. Method: Two hundred and twenty-three patient records were evaluated (58 women and 116 men). They had an average age of 34.54 (± 19.05) years and were referred by the orthopedic clinic of this hospital. Results: of the cases studied, wrist and hand injuries had the highest incidence (60.99%), followed by injuries of the shoulder (20.63%), elbow (12.55%), arm (3.59%) and forearm (2.24%). In injuries of wrist and hand, the trauma mechanism with the highest percentage was the motorcycle accident, associated with multiple handbone fractures. Falling down, motorcycle accidents, and falling off a ladder were the mechanisms of injury correlated with proximal humerus fractures, shoulder dislocations, and broken scapulas, respectively. Conclusion: the incidence of injury, trauma mechanism, and characteristics of the population was verified and further improvements in protocols for specific disorders and prevention can be made.


Subject(s)
Humans , Male , Female , Upper Extremity , Rehabilitation Centers , Shoulder/injuries , Health Profile , Hand Injuries/epidemiology , Forearm Injuries/epidemiology , Arm Injuries/epidemiology , Wrist Injuries/epidemiology , Epidemiology, Descriptive , Cross-Sectional Studies , Medical Records
14.
Acta ortop. bras ; 21(1): 34-39, jan.-fev. 2013. ilus
Article in Portuguese | LILACS | ID: lil-670855

ABSTRACT

Objetivo: Realizar um estudo biomecânico de quatro técnicas de fixação das fraturas em quatro partes da cabeça umeral. Métodos: A fratura foi reproduzida em 40 úmeros plásticos, divididos em grupos de dez conforme a técnica de fixação, cada uma delas empregando diferentes recursos de fixação, em configurações distintas. Os modelos umerais foram montados em uma escápula de alumínio, com tiras de couro mimetizando os tendões do capuz rotador, e submetidos a ensaios de encurvamento e de torção em uma máquina universal de ensaios, usando a rigidez relativa como parâmetro de avaliação. Montagens com o úmero intacto foram analisadas para comparação. Resultados: O comportamento biomecânico das técnicas de fixação variou dentro de uma ampla faixa, as montagens incluindo a placa DCP e os parafusos de 4,5mm de diâmetro sendo significantemente mais rígidos do que as montagens com os fios de Kirschner e os parafusos 3,5 mm de diâmetro. Conclusão: As quatro técnicas foram capazes de suportar cargas compatíveis com a demanda fisiológica, mas aquelas com a maior rigidez relativa devem ser as preferidas para finalidades clínicas. Trabalho experimental.


Objective: To carry out a biomechanical study of four techniques for fixation of four-part humeral head fractures. Methods: The fracture was reproduced in 40 plastic humeri, divided into groups of ten according to the fixation technique, each one employing different fixation resources, in different configurations. The humeral models were mounted on an aluminum scapula, with leather straps simulating the rotator cuff tendons, and submitted to bending and torsion tests in a universal testing machine, using relative stiffness as an evaluation parameter. Assemblies with intact humeri were analyzed for comparison. Results: The biomechanical behavior of the fixation techniques varied within a wide range, where the assemblies including the DCP plate and the 4.5mm diameter screws were significantly more rigid than the assemblies with the Kirschner wires and the 3.5mm diameter screws. Conclusion: The four fixation techniques were able to bear loads compatible with the physiological demand, but those with higher relative stiffness should be preferred for clinical application. Laboratory investigation.


Subject(s)
Humans , Biomechanical Phenomena/physiology , Bone Screws , Humeral Head/physiology , Fracture Fixation, Internal/methods , Scapula , Shoulder Fractures , Torsion, Mechanical
15.
Acta ortop. bras ; 21(1): 46-51, jan.-fev. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-670858

ABSTRACT

Objetivo: Medir a velocidade de propagação do ultrassom (VU) através de uma osteotomia transversal em tíbias de ovelha, antes e após a fixação com uma placa DCP. Métodos: Foram utilizadas dez montagens de uma placa DCP com o segmento diafisário das tíbias, no qual era feita uma osteotomia transversal. Foi realizada a medida subaquática transversal, nos planos coronal e sagital, e axial da VU, no osso íntegro, nas montagens sem osteotomia e, depois, com osteotomia sem e com a compressão axial pela placa DCP; comparações estatísticas foram feitas ao nível de significância de 1% (p<0,01). Resultados: Em comparação com a montagem com o osso intacto, a VU diminuiu com a adição da osteotomia e aumentou com a compressão axial, com significância somente para a modalidade axial de medida da VU. Conclusão: Concluiu-se que esse dado pode ser aplicável ao acompanhamento pós-operatório das osteossíntese com placa DCP, com a capacidade de demonstrar quando esta se torna ineficiente. Trabalho experimental.


Objective: To measure the ultrasound propagation velocity (UV) through a tibial transverse osteotomy in sheep, before and after the fixation with a DCP plate. Material and methods: Ten assemblies of a DCP plate with the diaphyseal segment of tibiae, in which a transverse osteotomy was made, were used. Both coronal and sagittal transverse and the axial UV were measured, first with the intact bone assembled with the plate and then with the uncompressed and compressed osteotomy; statistical comparisons were made at the 1% (p<0.01) level of significance. Results: Compared with the intact bone assembly, axial UV significantly decreased with the addition of the osteotomy and significantly increased with compression, presenting the same behavior for the other modalities, although not significantly. Discussion and conclusion: In accordance with the literature data on the ultrasonometric evaluation of fracture healing, underwater UV measurement was able to demonstrate the efficiency of DCP plate fixation. The authors conclude that the method has a potential for clinical application in the postoperative follow-up of DCP plate osteosinthesis, with a capability to demonstrate when it becomes ineffective. Laboratory investigation.


Subject(s)
Animals , Acoustics , Bone Plates , Fracture Fixation, Internal , Osteotomy , Sheep , Sound , Ultrasonics/methods
16.
Acta ortop. bras ; 21(6): 333-335, 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-689706

ABSTRACT

OBJETIVO: Analisar e comparar as características dos pacientes com sindactilia congênita com os dados da literatura.MÉTODOS: Estudo retrospectivo baseado na análise do prontuário médico de 47 pacientes tratados em um período de 10 anos.RESULTADOS: Dos pacientes, 33 (70%) eram do sexo masculino e 14 (30%) do feminino. O número total de sindactilias foi de 116. A mão direita foi acometida em 19 casos (40%), a mão esquerda em 12 (24%) e em 17 (36%) o acometimento foi bilateral. Dezesseis (34%) pacientes possuíam síndromes genéticas. Entre os 31 (66%) não-sindrômicos, 12 (39%) apresentavam sindactilias isoladas e 19 (61%) associação com outras malformações da mão. O terceiro espaço foi acometido 45 (39%) vezes, seguido do quarto espaço com 35 (30%), do segundo com 22 (19%) e do primeiro com 14 (12%). As sindactilias simples foram encontradas 68 (59%) vezes, sendo completas em 44 (65%) situações e parciais em 24 (55%). As complexas foram identificadas 48 (41%) vezes.CONCLUSÃO: Os resultados obtidos na presente série são muito semelhantes aos dados encontrados na literatura. Estudo Epidemiológico.


OBJECTIVE: To assess and report clinical data from patients with syndactyly.METHODS: A retrospective review of 47 patients treated between April 2002 and April 2012.RESULTS: Among the 47 analyzed patients, 33 (70%) were male and 14 (30%) female. The total number of syndactylies was 116. The right hand was affected in 19 patients (40%), the left hand in 12 (24%) and 31 (36%) were bilaterally compromise. Sixteen patients (34%) also presented genetic syndromes. Among the 31 (66%) patients without syndromes, 12 (39%) had isolated syndactyly and 19 (61%) presented association with other hand anomalies. The third web space was affected 45 (39%) times; the fourth, 35 (30%) times; the second, 22 (19%) times and the first web space 14 (22%) times. Simple syndactyly was found 68 (59%) times, complete syndactyly in 44 (65%) and incomplete in 24 (55%). Complex syndactyly was found 48 (41%) times.CONCLUSION: The results in this study are similar to the literature. Epidemiological Study.


Subject(s)
Humans , Male , Female , Syndactyly/surgery , Syndactyly/epidemiology , Epidemiologic Studies , Medical Records , Retrospective Studies
17.
Acta fisiátrica ; 19(4): 216-221, dez. 2012.
Article in English, Portuguese | LILACS | ID: lil-689490

ABSTRACT

A avaliação funcional da sensibilidade é essencial para analisar o estado, recuperação, e efetividade do programa de tratamento em pacientes que sofreram perdas decorrentes de deficiência motora e/ou sensitiva, após lesões nervosas periféricas. Estas lesões geram a interrupção das sensações ocasionando a perda da sensibilidade e uma significante perda funcional da mão. Objetivo: O objetivo deste estudo foi correlacionar o teste funcional Pick-Up de Moberg com o teste de limiar sensitivo Estesiômetro SORRI® na reconstrução do nervo mediano. Métodos: Foram analisados 14 homens com idade entre 18 e 40 anos que sofreram ferimento corto-contuso na região volar do punho e tratamento cirúrgico há pelo menos um ano de pós-operatório. Foram utilizados para a avaliação da sensibilidade cutânea o Estesiômetro SORRI® e o teste Pick-Up de Moberg modificado, no qual a avaliação foi dividida em duas fases, olhos abertos e fechados, ambas realizadas com a mão dominante e não dominante, e em duas etapas com diferentes avaliadores, sendo repetidas três vezes em cada mão. A sequência dos avaliadores foi sorteada e mantida durante toda a avaliação. Na análise dos dados foi utilizado o coeficiente de Pearson e aplicado o teste não-paramétrico de Mann-Whitney com o nível de significância ? = 0,05. Resultados: A média da idade foi de 27,14 anos (±6,43), com maior frequência entre 21 a 30 anos sendo que 64% apresentaram lesão na mão dominante. O coeficiente de Pearson (r) entre o Estesiômetro e o Pick-Up foi entre 0,5 e 0,7, com p-valor <0,05. Os intervalos de confiança e p-valores dos testes de Mann-Whitney não indicaram diferenças estatisticamente significantes. Conclusão: Apesar do teste Pick-Up de Moberg não possuir medidas padronizadas, na amostra estudada pode-se concluir que existe correlação entre o teste funcional e o teste de limiar sensitivo. Novos estudos são necessários para a validação e confiabilidade de ambos os métodos.


Functional assessment of sensitivity is essential to analyzing the status, recovery, and effectiveness of the treatment program for patients who have suffered losses due to physical and / or sensory disability after peripheral nerve injuries. Such losses of sensation lead to a significant loss of hand function. Objective: The purpose of the present study was to establish a correlation between functional and sensory threshold tests after a peripheral nerve lesion in the hand. Methods: Fourteen men aged 18 to 40 years, who had bruises and cut injuries at the volar region of the wrist resulting in median nerve lesion, were selected for study. All the subjects were at least 1-year post-surgery. An esthesiometer SORRI® and a modified Moberg pick-up test were used. The test was divided into two phases, one with eyes open and the other with eyes closed. Also, the same test was performed by two different examiners. It was a "blinded" test that was performed three times, being repeated by the examiners according to a random sequence kept during the entire evaluation. Mean age and standard deviation were obtained during analysis in which Pearson's coefficient was calculated and the non-parametric Mann-Whitney test was applied at 5% significance. Results: The mean age was 27.14 years with a standard deviation of 6.43 years, with the lesions being more frequently seen in men aged 21 to 30 years. Also, 64% of the cases involved lesion of the dominant hand. Pearson's coefficient (r) regarding the correlation between sensory threshold test and Moberg pick-up test ranged from 0.5 to 0.7, which was statistically significant. Confidence intervals and p-values obtained from the Mann-Whitney test showed no statistically significant differences. Conclusion: One can conclude, therefore, that despite lacking standardized measures, the Moberg pick-up test correlated with the functional test. However, further studies are needed to support validation and reliability of the two methods.


Subject(s)
Adult , Peripheral Nerve Injuries/rehabilitation , Reproducibility of Results , Median Nerve/injuries
18.
Acta ortop. bras ; 20(3): 139-149, 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-640105

ABSTRACT

OBJETIVO: Avaliar a confiabilidade intra e interexaminadores e a reprodutibilidade da goniometria em relação à fotogrametria na mão, comparando os ângulos da abdução de polegar, flexão da AIFP do II dedo e flexão da AMCF do V dedo. MÉTODOS: PARTIciparam deste estudo 30voluntários foram divididos em 3 grupos, um grupo de 10 estudantes de Fisioterapia, outro por 10 fisioterapeutas e o terceiro com 10 terapeutas da mão. Cada avaliador realizou as medidas no mesmo molde de mão, utilizando o goniômetro e em seguidadois softwares de fotogrametria, o CorelDraw® e o ALCimagem®. RESULTADOS: Os resultados revelaram que os grupos e os métodos propostos apresentam confiabilidade interexaminadores no geral classificada como excelente (ICC 0,998 I.C. 95% 0,995 - 0,999). Na avaliação intraexaminadores, foi encontrado excelente nível de confiabilidade entre os três grupos. Na comparação entre os grupos para cada ângulo e cada método, observou-se que não houve diferença significativa entre os grupos para a maioria das medidas. CONCLUSÃO: A goniometria e a fotogrametria são métodos confiáveis e reprodutíveis para avaliação de medidas na mão. Porém, pela escassez de referências semelhantes, necessita-se de estudos aprofundados para definição de parâmetros de normalidade entre os métodos nas articulações da mão. Nível de Evidência II, Estudo Diagnóstico.


OBJECTIVE: To evaluate the intra and inter and reproducibility of goniometry compared to photogrammetryin hand, comparing the angles of abduction of thumb flexion, flexion of proximal interphalangeal joint of the index finger and flexion of the metacarpophalangeal joint of the fifth finger. METHODS: The study included 30 volunteers were divided in to three groups, one group of 10 students of physiotherapy for 10 physiotherapist sand other third with 10 therapist shand. Each examiner performed the measure mentsin the same mold by hand, using the goniometer and then two photogrammetry software, Corel Draw® and ALCimagem®. RESULTS: The results revealed that the groups and the methods proposed inter examiner reliability have generally rated as excellent (ICC 0.99895% CI0.995 to 0.999) In assessing rater was found excellent level of reliability among the three groups. Incomparison between groups for each angle and each method, we found that there was no significant difference between groups for most measures. CONCLUSION: Goniometry and photogramme tryare reliable and reproducible methods to evaluate measures in hand. However, the scarcity of similar references, it requires detailed studies to define normal parameters of the methods in the joints of the hand. Level of Evidence II, Diagnostic Study.


Subject(s)
Humans , Male , Female , Arthrometry, Articular , Hand Joints , Photogrammetry , Range of Motion, Articular , Reproducibility of Results
19.
Acta ortop. bras ; 20(3): 184-190, 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-640112

ABSTRACT

OBJETIVO: Avaliar a influência da espessura do osso cortical sobre a velocidade de propagação do ultrassom (in vitro). MÉTODO: Foram utilizadas 60 lâminas ósseas confeccionadas a partir do fêmur de bovinos, com diferentes espessuras, variando de 1 a 6mm (10 de cada). As medidas da velocidade do ultrassom foram realizadas por aparelho projetado para este fim, utilizando técnica subaquática e por contato direto com auxílio de gel de acoplamento. Os transdutores foram posicionados de duas maneiras diferentes; opostos entre si, com o osso entre eles, sendo a medida chamada de transversal; e, paralelos na mesma superfície cortical, sendo a medida chamada de axial. RESULTADOS: Com o modo de transmissão axial, a velocidade de propagação do ultrassom aumenta conforme a espessura do osso cortical aumenta, independente da distância entre os transdutores, até a espessura de 5mm, mantendo-se constante após. Não houve alteração da velocidade quando o modo de transmissão foi transversal. CONCLUSÃO: A velocidade de propagação do ultrassom aumenta com o aumento da espessura da cortical óssea, no modo de transmissão axial, até o momento em que a espessura supera o comprimento da onda, mantendo a velocidade constante a partir de então. Nível de Evidência: Estudo Experimental.


OBJECTIVE: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. METHODS: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. RESULTS: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. CONCLUSION: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.


Subject(s)
Animals , Cattle , Femur/ultrastructure , Outflow Velocity Measurement , Lamins , Transducers , Ultrasonics
20.
Acta ortop. bras ; 20(2): 93-97, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-622370

ABSTRACT

OBJETIVO: Analisar a eficiência do tratamento com a estimulação elétrica de alta voltagem (EEAV) em três diferentes locais, aplicada precocemente na regeneração do nervo ciático submetido à lesão por esmagamento, e avaliada através do índice funcional do ciático (IFC), em ratos. MÉTODO: Após o esmagamento, 57 ratos foram submetidos à EEAV catódica nos parâmetros: frequência de 50Hz, 100V de tensão, 20 minutos diários, 5 dias por semana. Os ratos foram divididos aleatoriamente em: grupo controle; grupo gânglio; grupo gânglio + músculo; grupo músculo e; grupo simulado. O IFC foi avaliado semanalmente durante sete semanas, partindo do pré-operatório até a 6ª semana pós-operatória. RESULTADOS: Em comparação ao grupo controle, os resultados mostraram desempenho significativamente superior do grupo gânglio nas três primeiras semanas, e do grupo gânglio + músculo na 3ª semana, enquanto o grupo músculo teve desempenho significativamente negativo na 4ª e 6ª semanas. CONCLUSÃO: a EEAV aplicada precocemente, foi positiva no tratamento da região da medula e gânglio da raiz nervosa do ciático com o eletrodo dispersivo na região lombar contralateral ou no músculo gastrocnêmio. Porém, proporcionou efeitos negativos no tratamento com eletrodo ativo no músculo gastrocnêmio e dispersivo na coxa contralateral. Nível de evidência II, Estudo prospectivo comparativo.


OBJECTIVE: To analyze the efficiency of high voltage pulsed current (HVPC) with early application in three different sites, in the regeneration of the sciatic nerve in rats submitted to crush injury, the sciatic functional index (SFI) was used to assess the functional recovery. METHODS: After crushing of the nerve, 57 animals were submitted to cathodal HVPC at frequency of 50Hz and voltage of 100V, 20 minutes per day, 5 days per week. The rats were divided into five groups: control group; ganglion group; ganglion + muscle group; muscle group; and sham group. The SFI was determined weekly for seven weeks, from the preoperative period to the 6th postoperative week. RESULTS: Compared with the control group, the results showed a significantly better performance of group 2 for the first 3 weeks; group 3 showed significantly better performance in the third week; and group 4 showed a significantly negative performance during the 4th and 6th weeks. CONCLUSION: Early application of HVPC had a positive effect in the treatment of the spinal cord region and the sciatic nerve root ganglion with a dispersive electrode on the contralateral lumbar region or on the gastrocnemius. However, HVPC had a negative effect in the treatment with an active electrode on the gastrocnemius and a dispersive electrode on the contralateral thigh. Level of evidence II, Prospective comparative study.


Subject(s)
Male , Rats , Lumbosacral Region , Sciatic Nerve/injuries , Sciatic Neuropathy/rehabilitation , Spinal Cord , Transcutaneous Electric Nerve Stimulation , Nerve Regeneration , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL